Product Details:
| Minimum Order Quantity | 1 Piece |
| Measuring Range | 2000 um |
| Resolution | 0.1 µm |
| Probe Type | Built In |
| Display Type | LCD |
| Accuracy | (2.5%+1m) C |
| Data Interface | USB |
| Brand | DFT -222 |
| Power Source | AAA Battery |
| Substrate Type | F And NF |
| Type | F / NF |
Features:
• 128*128 dot matrix LCD display, standard menu operations.
• Two measure mode: single and continuous.
• Two group mode: direct (DIR) and general (GEN), readings will be lost when power off in direct
mode, and not be lost in general mode.80 readings can be stored for each group.
• Zero point calibration and multi-point calibration (up to 4 points) for each group.
• User can recall, delete specified readings, or delete group readings.
• Statistics display: Mean minimum, maximum and standard deviation.
• Three probe mode :auto, magnetic and eddy current.
• User can set high or low limit alarm for each group.
• Power off automatic
Product Details:
| Minimum Order Quantity | 1 Piece |
| Substrate Type | F And NF |
| Measuring Range | 1500 um |
| Resolution | 0.5 µm |
| Type | F / NF |
| Probe Type | External Probe |
| Display Type | LCD |
| Accuracy | 1 % of reading |
| Minimum Sample Thickness | 0.4 mm |
DIGITAL COATING THICKNESS GAUGE
F/NF COMBINED MODEL.
Product Details:
| Minimum Order Quantity | 1 Piece |
| Measuring Range | 1350 |
| Resolution | 0.1 um |
| Probe Type | Cabled Probe |
| Display Type | LCD |
| Minimum Measurement Area | 6mm |
| Accuracy | ±1 µm |
| Minimum Sample Thickness | 0.3 mm |
| Size | 115 x 57 x 26 mm |
| Color | black |
| Model Name / Number | CM801E |
| Data Interface | No Interface |
| Brand | Mextech |
| Power Supply | 3 x 1.5V AAA batteries |
| Battery Life | As per useing |
| Power Source | AAA Battery |
| Substrate Type | F And NF |
| Type | F / NF |
DIGITAL COATING THICKNES GAUGE
MODEL CM801E
With External Probe.
Display: 4 Digit Display (10mm LCD)
Measuring Range: 0~1350µm/0~53mil
Accuracy: ±2~3%n or ±2.5µm or 0.1mil (Whichever is the greater)
Resolution: 0.1 um (0~99.9um), 1 um (over 100um)
Operating Principle: Magnetic Induction (F), Min. Measuring Area: 6 mm , Min. Sample Thickness:0.3mm
Product Details:
| Minimum Order Quantity | 1 Piece |
| Scale Range | 0–50 µm |
| Number Of Channels | 2 Channels |
| Channel Width | DOUBLE GROOVE |
| Gauge Length | 150 mm |
| Scraper Included | Yes |
| Size | 175 X 65 X 13 (LxBxH)mm |
| Color | Silver |
| Usage/Application | For Laboratory |
| Finish | Ground |
| Country of Origin | Made in India |
| Material | Stainless Steel |
| Measuring Range | 100 Um Max , 50, 25, 10 |
| Is It Waterproof | Waterproof |
Backed by a rich industrial experience, we are engaged in bringing forth a comprehensive variety of Hegman Gauge. Basically, these Hegman Gauges are commonly used to determine the quality control. Hegman Gauges are appreciated due to its features such as easy-to-use, relatively inexpensive production and quality control tools.
As per BS 3900 C6 ISO 1524 ASTM D 1210 IS:101 (Part 1/SEC-5) 1989.
Available in different sizes :-
1) 0-10 micron
2) 0-25 micron
3) 0-50 micron
4) 0-100 micron
Using Instructions
The gauge is wiped down and cleaned before use. At the starting point of each channel, add two drops of the prepared pain reliever. By adjusting the scraper to a 90D angle, scrape it down on the Paint Channel blur. Not the micron number from the scale and also the Hegemann gauge number from the Hegemann scale. In this way we can determine the size of the pigments from which the paint is made.
Additional Information:
Product Details:
| Measuring Range | 1500 um |
| Resolution | 0.1 um |
| Probe Type | Built In |
| Display Type | Backlit LCD |
| Minimum Measurement Area | 25 X 25MM |
| Accuracy | ±1 µm |
| Model Name / Number | DFT-821 |
| Brand | HTC |
| Substrate Type | F And NF |
| Type | F / NF |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Size | 0-25 microns,0-50 microns,0-100 microns,0-10 microns |
| Color | SS |
| Usage/Application | Paint testing industry |
TQCSHEEN’ NETHERLANDS Make Precision Hegman Gauge.
Model: VF2111 (Double channel version.)
Range: 0-25,0-50,0-100,0-10 microns
Supplied with Calibration Certificate.
Product Details:
| Minimum Order Quantity | 1 Piece |
| Brand | SST CHC-2021 |
| Model Name/Number | SST- CHC-2021 |
| Usage/Application | Industrial |
| Display Type | Analog |
| Standards | ISO2409-1992, GB/T9286-98, BS3900E6 AND ASTMD3359 STANDARD |
| Volume | 1kg |
| Size | 1mm , 2mm and 3 mm |
CROSS CUT ADHESOIN TEST KIT (HSN CODE – 8208)This instrument is designed for assessing the resistance of paint or relatedcoatings to separation from substrates when a right-angle lattice pattern iscut into the coating, penetrating through to thesubstrate.The Cross Hatch Cutters confirm with therequirements of: BS 3900E6; BS/EN ISO 2409; ASTM D 3359; GB/T 9286Main Technical Parameters:Six working side blades: When the blade edge is notsharp enough, users can loosen the boat type nut and top thrust screw tochange blade.Multi-cutting blades spacing: 1mm/2mm/3mmThe number of square: 25 squares/100squares
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Tape Width | 24 mm |
| Tape Length | 50 m |
| Model Name/Number | P 254 , P 253 |
| Application Surface | Painted Surfaces |
| Brand | saint gobain |
| Residue Free Removal | Yes |
| Usage/Application | Paint Checking |
| Country of Origin | Made in India |
Adhesive Tape Size- 2.50cm x 65 mtrs
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Size | 5 liters |
| Material | Stainless Steel |
REMI LABORAOTRY STIRRER
Product Details:
| Minimum Order Quantity | 1 Piece |
| Number Of Cups | 1 |
| Model Name/Number | SST-B4 |
| Brand | SST |
| Material | BRASS |
| Usage/Application | Industrial |
| Country of Origin | Made in India |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Machine Type | Manual |
| Number Of Pencil Grades | 12 |
| Display Type | Analog |
| Test Angle | 45 degree |
| Parameter | HRC |
| Test Force | 500 n |
| Brand | SHAKUNTLA SCIENTIFIC |
| Pencil Grade Range | 6B to 6H |
| Compliance Standard | ASTM D3363 |
| Automation Grade | Manual |
| Material | Stainless Steel |
| Weight | 1000g, 750g, & 500 Grams |
| Tester Type | Pencil |
| Load Capacity | 1000G, 750G, 500G |
| Packaging Type | BOX |
| Measuring Direction | 45D |
Pencil Hardness tester with Pencils Set of 12 Nos. Stedtler German Make.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Type | Table top |
| No of light sources | 6 |
| Number Of Lights | 5, 5 |
| Viewing area | 450x400mm |
| Std Glass Filters | 5 Filters |
| Light sources | D65; TL84; CWF; UV |
| Mobility | Benchtop |
| Application | Textile, Paint, Printing, Packaging |
| Control | Manual |
| Angle Of Viewing Booth | 45D |
| Cwf Light | 1 |
| Number of Artificial Daylight | 1 |
| Number of Cool White Light | 2NOS. |
| Number of Phase | Single phase |
| Tf Light | 1 |
| Body material | MS powder coat |
| Uv Light | 1 |
| Surface Finish | Powder coating |
| Country of Origin | Made in India |
Cabinet is made out of Powder Coated M.S. Sheet, Inside Color N7 Munsell neutral grey.
Standard Model With Following Light Sources 5 Lights:
D65 – 02 Nos.
TL 84 – 01 Nos.
Ultra violet – 01 No.
Tungsten Filament Light – 4 Nos. (60 W/Light)
Cool White Light (CWF) – 01 Nos
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage | Lab Instruments |
| Capacity | 10 L |
| No Of Shelves | 1 Shelf |
| Material | Mild Steel |
| Tube Material | Quartz Glass |
| Lamp Type | UV LED |
| Power | 8 W |
| Wavelength | short U.V (254nm) or long U.V. (365nm) |
| Body Material | MS Powder Coated |
| Light Source | U.V. Fluorescence Viewing Cabinet LongWave, Short Wave and Florescence tube |
| Color | BLUE |
| Automation Grade | Manual |
| Door Type | Single Door |
| Power Source | SINGLE PHASE |
| Brand | SST |
| Wave Length | short U.V (254nm) or long U.V. (365nm) |
| Display Type | manual |
| Model Name/Number | SST-1UV |
| UV Tube | LONG WAVE, SHORT WAVE |
| Country of Origin | Made in India |
This compact machine is designed for T.L.C. plates up to 250x300mm. This is also suitable for observing either fluorescence or quenching of fluorescence with either short U.V (254nm) or long U.V. (365nm) of column or paper chromatograms, bacterial or fungal cultures, a plant specimen, a number of other laboratories & investigative work.
Construction:-
The external case is made of thick steel. Often with strong seamless welding & covered with a thick layer of epoxy-based polyester paint, which provides a strong, highly scratch & chemical resistant surface. The black inside finish of the cabinet prevents any reflection of the U.V. radiation, which protects the eyes. This dual wave mechanism is provided with 1 short wave U.V. tube enveloped with a precision optical filter, which emits mostly short wave U.V of mercury line 254 nm with high efficiency & a low-pressure mercury discharge tube with black woods glass envelop & a special phosphor coating inside the envelope to produce pre-dominantly long U.V. Output 365 nm with high efficiency. A fluorescence tube is provided for visible light. An eye-protective glass window is provided on the top front for viewing the samples & inside the chamber.
U.V. Chromatography Inspection Cabinet, One long wave:
One long wave for viewing & detecting prepared substance on T.L.C. plates and a number of other laboratory & investigation work. This cabinet is fitted with one long wave U.V. tube & one fluorescence tube for visible light. An eye-protective glass window is also provided on the top front for viewing the samples.
U.V. Chromatography Inspection Cabinet, Two long waves:
Two long waves for viewing & detecting prepared substance on T.L.C. plates & a number of other laboratory & investigation work. This cabinet is fitted with two U.V. tubes of different wavelengths & a fluorescence tube for visible light. An eye protective glass window is also provided on the top front for viewing the samples.
U.V. Fluorescence Viewing Cabinet (Triple Wave)
This compact machine is provided with 3 separate U.V. sources one for short U.V (Enveloped with precision optical filter(254 nm), one for middle U.V. (312 nm) one for long U.V. (365 nm), fluorescence tube is provided for visible light.
Additional Information: